SX-DH series high-speed double-gun dual-system refrigerant filling machine is suitable for bus air conditioning, central air conditioning, heat pump, solar energy, large refrigerant unit and other places. The range of filling can be customized.

Device Description: Omron PLC, data module, Omron/Vylon touch screen, Germany RHEONIK/ Germany Kewell high precision mass flowmeter, Germany Leybold/赛赛/ULVAC vacuum pump, pneumatic vacuum diaphragm valve, PON100/TTR91 Germany Leybold high sensitivity vacuum sensor, Adopting American Henkel movement pure pneumatic high efficiency booster pump (CSAIXI), SC160X100-S pure pneumatic intelligent balance cylinder (CSAIXI), SAIXI-S2 rear guide plunger charging gun

产品描述

Equipment Description:

Omron PLC, data module, Omron / Vinyl touch screen.      
Germany RHEONIK / Germany Cowell high precision mass flow meter.      
Germany Leybold / Saixi / ULVAC vacuum pump, pneumatic vacuum diaphragm valve.   
PON100/TTR91 Germany Leybold high sensitivity vacuum sensor.       
Adopting the American Henkel movement pure pneumatic high efficiency booster pump (CSAIXI).
SC160X100-S pure pneumatic intelligent balance cylinder (CSAIXI).        
The SAIXI-S2 rear ejector pin is filled with a gun.                       
 

Technical indicators:  

Name Name

SX-DH02

 SX-DH04   

  SX-DH06

Fill with refrigerant : R134a, R22 , R410a, R404, R407C, R406a   etc. HFC, HCFC  series of refrigerants; 

Charging the refrigerant 

Charge amount

10-9999  

 10-19999   

10-99999

Filled volume(g)

 fill speed   

60-80  

80-120

100-160

Filling speed(g/s)

 Traffic Resolution     

 ±0.1g  

  ±0.1g  

  ±0.1g  

Resolution  

Measurement method

German original mass flow meter

Measurement metthods    

Mass flowmeter  

Number of preset channels

100 product models can be set

The preset number of channels

100 Kinds of product models can be set

Filling accuracy    100g≤±0.5g,100g out side≤±0.5%

500g≤±1%,500g out side≤±0.5g%     

Charging precision  

Local vacuum  

≤8Pa

≤8Pa

≤8Pa

The machine cacuum

Vacuum rate

8L/S

8L/S

8L/S*2

Vacuum speed

Detecting vacuum

 8-300Pa

8-500Pa

8-500Pa

Detection Vacuum

Consumes compressed air

≥0.5-0.7MPa

Consumption of compressed air capacity

Power and rated power

AC220V/380V 50HZ /1.5-4.0KW

Power supply and power rationg